The Hydraulics, Inc. Rapid Response Torque Control (pressure compensator) provides control of the swashplate angle within the pump of a hydrostatic closed-loop system, thereby giving precise control of the output pressure of the pump. The speed at which the pressure control system reacts, provides protection for the prime mover and the driven load.
The rapid response torque control will work even in the systems that may require the pump to be driven over-center in order to maintain constant pressure in the high pressure loop. Torque control kits are available to provide pressure control for one or both ports of the hydrostatic pump, and for systems involving two transmissions driving a common load.
Application
The torque control system has been applied to Dynapower, Eaton, and Sundstrand hydrostatic drives. The schematics shown herein are as applied to Sundstrand Series 20 thru 27 and are for reference to other manufacturers systems. Hydraulics, Inc. is not responsible for the effects of applications of the rapid response control to Dynapower, Eaton, Sundstrand, or other company products and their warranties.
Rapid response Torque Control Data For Controlling Pump Output pressure at:
KITS FOR PORT “A” OR “B” | PORT “A” OR “B” | |||
---|---|---|---|---|
The following chart list components for controlling port “A” OR “B” in a manual, remote, or panel mount kit. | KIT A2115 | KIT A2115R | KIT A2115P | |
Part No. | Description | Manual | Remote | Panel Mount |
2104 | Check Valve | 1 | 1 | 1 |
2106 | Remote Pressure Control | 1 | ||
2115 | Compensator (Manual) | 1 | ||
2115A | Compensator (Remote) | 1 | ||
2115C | Compensator (Panel Mount) | 1 | ||
2118 | Relief Valve | 1 | 1 | 1 |
71101 | Internal Port Plug | 1 | 1 | 1 |
SCHEMATIC | ||||
PICTORAL SCHEMATIC |
KITS FOR PORT “A” & “B” | PORT “A” & “B” | |||
---|---|---|---|---|
The following chart list components for controlling port “A” & “B” in a manual, remote, or panel mount kit. | KIT B2115 | KIT B2115R | KIT B2115P | |
Part No. | Description | Manual | Remote | Panel Mount |
2104 | Check Valve | 2 | 2 | 2 |
2106 | Remote Pressure Control | 2 | ||
2114 | Shuttle Valve | 1 | 1 | 1 |
2115 | Compensator (Manual) | 2 | ||
2115A | Compensator (Remote) | 2 | ||
2115C | Compensator (Panel Mount) | 2 | ||
2118 | Relief Valve | 1 | 1 | 1 |
71101 | Internal Port Plug | 2 | 2 | 2 |
SCHEMATIC | ||||
PICTORAL SCHEMATIC |
KITS FOR PORT “A” Slaved | PORT “A” Slaved | |||
---|---|---|---|---|
The following chart list components for controlling port “A” slaved” in a manual, remote, or panel mount kit. | KIT C2115 | KIT C2115R | KIT C2115P | |
Part No. | Description | Manual | Remote | Panel Mount |
2104 | Check Valve | 2 | 2 | 2 |
2106 | Remote Pressure Control | 1 | 1 | 1 |
2115 | Compensator (Manual) | 1 | ||
2115A | Compensator (Remote) | 1 | ||
2115C | Compensator (Panel Mount) | 1 | ||
2116D | Compensator Slave (Preset) | 1 | 1 | 1 |
2118 | Relief Valve | 2 | 2 | 2 |
71101 | Internal Port Plug | 2 | 2 | 2 |
SCHEMATIC | ||||